Input Voltage: |
28 Vdc NOM., 18 to 32 Vdc |
Input Current: |
4.7 Amps typ at 28 Vdc input & @ FL 0.2 Amps maximum at no load |
Output Voltage: |
0-5 Vdc regulated |
Output Current: |
0-20 Amps continuous |
Regulation: |
3% for load, 2% for line and 3% for temperature |
Ripple: |
50 mVpp maximum |
Overload(OL): |
Deliver 110% output power for 2 hours |
Protection(OL): |
Withstands without damage or degradation load exceeding 110% to an output short circuit. Unit delivers rated output power upon removal of the overload condition |
Protection(SC): |
Under a output short circuit condition, the input current folds back and the output current is limited to 30 amperes |
Protection(OV): |
Output voltage is limited to 6.5 Vdc maximum |
Soft-Start: |
Minimum soft start delay of 200 mSec at full load is provided during an application of step input voltage to reduce output in rush current to cold (low) resistance of incandescent lamps. |
Shutdown(SD): |
Output shuts down when input voltage is below 13 Vdc and above 42 Vdc |
Efficiency: |
75% typical |
Temperature: |
-55C to +71C |
Altitude: |
55,000FT |
Compliance: |
FAA TSO-C71 |
Environmental: |
DO-160C ENV. CAT F2ZBB(MLV)XXXDFSAAAXXXZKXX |
Connector: |
Unit mates with MS3106A16S-1S or MS3456W16-1S or the equivalent |
Finish: |
Gold iridite per MIL-C-5541 Class 1A |
Weight: |
1.0 LBS (454 grams) |
Size: |
2.00 H x 3.38 W x 5.25 L inches 50.8 H x 85.8 W x 133.3 L mm Less protrusion of connector and screw heads |