Input: |
28 VDC nom., 22-36 VDC, 4.3 ADC |
Output: |
100 Watts, 0-28 VDC, 3.6 ADC |
Output Ripple: |
8 mVpp typ. @ 25C,25 mVpp maximum. |
Regulation: |
2% for line, 2% load and 2% temperature. |
Output Control: |
Adjustable with external 5k ohm,1/2 W linear pot (rheostat) |
Protection (Overvoltage): |
Output voltage is limited to approximately 125% even though remote control rheostat opens or shorts or certain types of internal failures occur. |
Protection (Overload): |
Output current limit when overload exceeds 125% of rating. |
Protection (Reverse Polarity): |
Input has reverse polarity diode in shunt to open 3 to 5 Amp. input C.B.and clip negative transients |
Efficiency: |
83% |
Input Circuit Breaker: |
5-6 Amp |
Temperature & Altitude: |
-50C to +70C @ mounting flange and at 55,000 ft.MIL-STD-810C Temperature and Altitude,Method 504.1, Proc 1, Cat 5. |
Size: |
1.6" H x 2.0" W x 5.0" L. 4.1 cm H x 5.1 cm W x 12.7 cm L |
Weight: |
0.6 lbs. (272 grams). |
Compliance: |
FAA TSO-C71 |