SC50 Static Inverters 400Hz 500 VA
(KGS products can only be shipped to U.S. address only.)
(DAI Part# SC50)
The SC50 is a lightweight, static inverter that utilizes the latest state of the art, solid state circuitry to invert a 28 VDC input to a 115 VAC, 400 Hz sine wave output.
Design features include a crystal controlled oscillator for output frequency stability and a pulse-width-modulated square to sine wave power conversion scheme for efficient and reliable operation.
The SC50 is primarily designed to power airborne and ground instruments, compasses, gyros, radars and navigation equipment.
|
|
Input Voltage: |
28 VDC. (nominal). 20 VDC to 36.5 VDC range. |
Input Current: |
20.7 ADC at full load. 0.5 ADC at no load. |
Output Voltage:
|
+5%, -7% (±2% typ. on 115 V).
|
Output Power:
|
500 VA total of 115 V & 26 V.
|
Output Frequency: |
400 Hz ± 1.0 Hz. |
Phase & Waveform: |
Single phase & sinusoidal. |
Harmonic Distortion: |
0.7% (nominal), 3% max. |
Power Factor: |
+.8 to -.8 |
Efficiency: |
87% (nominal). |
Regulation: |
1% Line, 1% Load, 2.5% Temp. |
Weight: |
4.9 lb. (2.22 kg) |
Response Time: |
300 Usec (NL to FL) |
Overload Capacity: |
110% of rated output power for 2 hrs 150% of rated output power for 5 min |
Protection Circuits: |
The inverter will shutdown under the following conditions: Input Voltage >37.5 VDC ±1.0 VDC Input Voltage < 18.0 VDC ±1.5 VDC Internal high ambient temperature. Output short circuit condition. |
Remote On/Off: |
Yes. Ground Pin E to turn ON |
Operating Temp: |
-55 C to +71 C (-65 F to+160 F) |
Altitude: |
55,000ft. |
Environment: |
RTCA DO- 160C env. cat. F2ZBB(LV)XXXXXXBXAXXXZXXX |
Cooling: |
Thermostatically controlled brushless fan. |
Compliance: |
FAA TSO-C73 |
|
A |
Input +28 VDC |
B |
Output 115 VAC, 400 Hz |
C |
Output Common |
D |
Input Return, Chassis GND |
E |
Remote On/Off. GND to ON |
F |
N/C |
G |
Output 26 VAC, 400 Hz |
MATE |
MS3106A18-9S or Equiv. |
|
|