Temperature |
-40° to +70° (ambient) |
Humidity |
95% Non-considering |
28V Installation |
+20 to +33VDC 200 mA energized/60 mA non-energized |
14V Installation |
+12 to +18VDC 200 mA energized/60 mA non-energized |
28V Installation |
18.25 ±0.5VDC/18.25 +1.0, -0.5 @ 40°C |
14V Installation |
10.25 ±0.5VDC/10.25 +1.0, -0.5 @ 40°C |
Relay Energize Confirmation Time |
100 mSec minimum to 250 mSec maximum; the realay contacts must be confirmed withing this time period to ensure that the relays remain energized |
Interface Logic |
Ground seeking continuous input for relay energize capable of sinking 200 mA. Ground seekng localizer energize input capable of sinking 10 mA. |
Dimensions |
1.5"H x 5.6"W x 3.8"D |
Mounting |
Bulkhead, 4 each #10 or #8 screws |
Connector |