Input voltage(VDC) Normal/Abnormal |
22 to 32 20 to 37 |
24 to 32 18 to 36.4 |
24 to 32 20 to 36.4 |
Input Current(ADC) @ 28 VDC in
|
4.8 |
10.6 |
15.0 |
Output Power (Total) 115 VAC/26 VAC |
100 VA 100VA/60VA |
250 VA 250VA/150VA |
350 VA 350VA/150VA |
Efficiency(%) |
75 to 78 |
82 min |
80 min |
Weight |
5.2 lbs |
5.5 lbs |
5.6 lbs |
Output Voltage |
115VAC and/or 26VAC |
Phase/Wave Form |
Single/sine wave |
Frequency |
400 Hz ± 1% |
Amplification Distortion |
<7% (3% typical) |
Power Factor |
.8 to -.95 |
Input Over Voltage |
Operate up to 37VDC input while supplying full rated VA output power. Output voltage under this condition is 115 VAC &plugmn;5%-7% |
Input Transient Protection |
Withstands transients of 88V lasting 1 mSec on the 28 VDC input line |
Overload & Short Protection
|
Withstands without damage or degradation loads exceeding 150% of rated output to a dead short. Inverter delivers rated output on removal of above condition |
Altitude |
55,000' |
Temperature |
-65° F to +160° F (-55° C to +71° C) |
Humidity |
Tested to > 95% for 10 days, temperature was cycled between 75°F to 160°F |
Environmental |
Designed to meet RTCA paper DO-160
|